From f116c971a83ed2a1a5ae7ff25580f35e0aa0e82c Mon Sep 17 00:00:00 2001 From: Peter Willendrup Date: Wed, 3 Jul 2024 13:55:48 +0200 Subject: [PATCH] Updated test values according to new-nightly which is now restored... --- .../examples/SOLEIL/SOLEIL_ANATOMIX/SOLEIL_ANATOMIX.instr | 2 +- .../examples/SOLEIL/SOLEIL_LUCIA/SOLEIL_LUCIA.instr | 2 +- mcxtrace-comps/examples/SOLEIL/SOLEIL_MARS/SOLEIL_MARS.instr | 2 +- mcxtrace-comps/examples/SOLEIL/SOLEIL_PX2a/SOLEIL_PX2a.instr | 4 ++-- mcxtrace-comps/examples/SOLEIL/SOLEIL_ROCK/SOLEIL_ROCK.instr | 2 +- 5 files changed, 6 insertions(+), 6 deletions(-) diff --git a/mcxtrace-comps/examples/SOLEIL/SOLEIL_ANATOMIX/SOLEIL_ANATOMIX.instr b/mcxtrace-comps/examples/SOLEIL/SOLEIL_ANATOMIX/SOLEIL_ANATOMIX.instr index 056e9cd713..2c6c9ca48f 100644 --- a/mcxtrace-comps/examples/SOLEIL/SOLEIL_ANATOMIX/SOLEIL_ANATOMIX.instr +++ b/mcxtrace-comps/examples/SOLEIL/SOLEIL_ANATOMIX/SOLEIL_ANATOMIX.instr @@ -55,7 +55,7 @@ * EH3 | 165.7-174.1 | Guard slits; TXM sample stage and zone-plate table; microtomography sample stage; detector table | EH3 * EH4 | 197.2-208.5 | Guard slits; microtomography sample stage; detector table; X-ray grating interferometer | EH4 * -* %Example: -n 1e5 E0=17 Detector: psd_monitor_after_cc_I=1.14076e+18 +* %Example: -n 1e5 E0=17 Detector: psd_monitor_after_cc_I=8.7e+17 * * %Parameters * E0: [keV] Energy selected at the Undulator. diff --git a/mcxtrace-comps/examples/SOLEIL/SOLEIL_LUCIA/SOLEIL_LUCIA.instr b/mcxtrace-comps/examples/SOLEIL/SOLEIL_LUCIA/SOLEIL_LUCIA.instr index b743b2216b..d27a8584a4 100644 --- a/mcxtrace-comps/examples/SOLEIL/SOLEIL_LUCIA/SOLEIL_LUCIA.instr +++ b/mcxtrace-comps/examples/SOLEIL/SOLEIL_LUCIA/SOLEIL_LUCIA.instr @@ -13,7 +13,7 @@ * %Description * The HU52 undulator, a DCM, a fluorescence sample, and monitors. * -* %Example: E0=3 Detector: mon_spl_fluo_I=3.66859e+14 +* %Example: E0=3 Detector: mon_spl_fluo_I=1.9e+15 * * %Parameters * E0: [keV] Nominal energy at the Wiggler. diff --git a/mcxtrace-comps/examples/SOLEIL/SOLEIL_MARS/SOLEIL_MARS.instr b/mcxtrace-comps/examples/SOLEIL/SOLEIL_MARS/SOLEIL_MARS.instr index 0cd57c8023..804a587bc5 100644 --- a/mcxtrace-comps/examples/SOLEIL/SOLEIL_MARS/SOLEIL_MARS.instr +++ b/mcxtrace-comps/examples/SOLEIL/SOLEIL_MARS/SOLEIL_MARS.instr @@ -24,7 +24,7 @@ * * This model implements the XRD station for powders. * -* %Example: E0=16.99 Detector: detector_diffraction_I=3.13e+09 +* %Example: E0=16.99 Detector: detector_diffraction_I=2.3e+09 * * %Parameters * E0: [keV] Central energy to be emitted by the source diff --git a/mcxtrace-comps/examples/SOLEIL/SOLEIL_PX2a/SOLEIL_PX2a.instr b/mcxtrace-comps/examples/SOLEIL/SOLEIL_PX2a/SOLEIL_PX2a.instr index 1f549374c5..b6c6866ec9 100644 --- a/mcxtrace-comps/examples/SOLEIL/SOLEIL_PX2a/SOLEIL_PX2a.instr +++ b/mcxtrace-comps/examples/SOLEIL/SOLEIL_PX2a/SOLEIL_PX2a.instr @@ -28,8 +28,8 @@ * This is a simplified model with an Undulator, mirrors, a double crystal * monochromator, a sample stage and a detector. * -* %Example: E0=12.65 sample="Mo.lau" Detector: Eiger9M_I=2.50265e+11 -* %Example: E0=12.65 Detector: Eiger9M_I=5.94109e+14 +* %Example: E0=12.65 sample="Mo.lau" Detector: Eiger9M_I=3e+11 +* %Example: E0=12.65 Detector: Eiger9M_I=2.1e+15 * * %Parameters * E0: [keV] Energy selected at the Undulator. diff --git a/mcxtrace-comps/examples/SOLEIL/SOLEIL_ROCK/SOLEIL_ROCK.instr b/mcxtrace-comps/examples/SOLEIL/SOLEIL_ROCK/SOLEIL_ROCK.instr index f84cafc227..87f07e6409 100644 --- a/mcxtrace-comps/examples/SOLEIL/SOLEIL_ROCK/SOLEIL_ROCK.instr +++ b/mcxtrace-comps/examples/SOLEIL/SOLEIL_ROCK/SOLEIL_ROCK.instr @@ -44,7 +44,7 @@ * Manganese and chrome scan: mxrun SOLEIL_ROCK.instr E0=5.700,6.800 scan=1 sample_file=MnCr cc=2 -N100 * Pretty energy repartition monitor result: mxrun SOLEIL_ROCK.instr E0=17.000 cc=2 -n1e8 * -* %Example: E0=15.918 Detector: psd_monitor_I=2.13326e+07 +* %Example: E0=15.918 Detector: psd_monitor_I=6.9e+08 * * %Parameters * E0: [keV] Energy to hit, i.e. selected by the channel-cut monochromator