Skip to content

Commit

Permalink
Functional updates, documentation updates
Browse files Browse the repository at this point in the history
- Add BSD-3-Clause license
- Update documentation
- Add support for timestamp subtopics for monitoring purposes
- Add disclaimer, fix typos
  • Loading branch information
Gerrit Beine committed Jun 24, 2024
1 parent b3dea6a commit d150cba
Show file tree
Hide file tree
Showing 4 changed files with 116 additions and 27 deletions.
1 change: 1 addition & 0 deletions .gitignore
Original file line number Diff line number Diff line change
@@ -0,0 +1 @@
/fronius2mqtt.conf
27 changes: 27 additions & 0 deletions LICENSE.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,27 @@
Copyright (c) 2016-2024, Gerrit Beine
All rights reserved.

Redistribution and use in source and binary forms, with or without
modification, are permitted provided that the following conditions are met:

* Redistributions of source code must retain the above copyright notice, this
list of conditions and the following disclaimer.

* Redistributions in binary form must reproduce the above copyright notice,
this list of conditions and the following disclaimer in the documentation
and/or other materials provided with the distribution.

* Neither the name of fronius2mqtt nor the names of its
contributors may be used to endorse or promote products derived from
this software without specific prior written permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE
FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY,
OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
82 changes: 65 additions & 17 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -5,40 +5,88 @@ A Fronius HTTP API to MQTT bridge
Attention: This is a complete rewrite of the bridge.
While the old fronius2mqtt brigde used polling the inverters to fetch the data, the new version make use of the push feature provided by Fronius Symo.

The daemon offers no HTTP endpoints which can be configured in the configuration interface of each inverter.
The daemon offers now HTTP endpoints which can be configured in the configuration interface of each inverter.
It forwards the data directly to MQTT.

## Install

### Installation using Docker

```
docker run -it --rm --name fronius2mqtt -v fronius2mqtt.conf:/etc/fronius2mqtt.conf docker.io/gbeine/fronius2mqtt
```

### Native installation with Python venv

- clone the git repository
- ensure to have Python 3 with venv installed
- run the ```install``` script in the local directory
- run the `install` script in the local directory

## Configuration

### Device configuration

On the settings page for you Fronius device, select 'Push Service'.

Define an identifier for your device, e.g. `fronius1`, and add the following values:

| Field | Explanation |
|------------------|------------------------------------------------------------------------------|
| Name | As you like, only relevant on the device side |
| Data Format | Select one from the table below, choose HTTP Post |
| Interval | 10 sec, or use the default |
| Activate | Select |
| Server:Port | The hostname and port of your HTTP server, e.g. `smarthome.example.org:8080` |
| Upload file name | /path/identifier, e.g. `/current_data_inverter/fronius1` |
| Login | Not needed unless you use an authentication proxy |
| Proxy | Not needed unless you use a dedicated proxy server |

| Data format | URL path |
|-------------------------------------------------|---------------------------------------------------|
| Datamanager IO States | `/datamanager_io_states/<device identifier>` |
| SolarAPI v1 - CurrentData - Inverter | `/current_data_inverter/<device identifier>` |
| SolarAPI v1 - CurrentData - Meter | `/current_data_meter/<device identifier>` |
| SolarAPI v1 - CurrentData - Powerflow | `/current_data_powerflow/<device identifier>` |
| SolarAPI v1 - CurrentData - SensorCard | `/current_data_sensorcard/<device identifier>` |
| SolarAPI v1 - CurrentData - StringControl | `/current_data_stringcontrol/<device identifier>` |
| SolarAPI v1 - Logdata - Data | `/logdata_data/<device identifier>` |
| SolarAPI v1 - Logdata - Errors and Events | `/logdata_errors_and_events/<device identifier>` |
| SunSpec Datalogger v1.0b - inverter float model | - not yet implemented - |
| SunSpec Datalogger v1.2 - meter model | - not yet implemented - |

### fronius2mqtt.conf

Each configuration option is also available as command line argument.

- copy ```fronius2mqtt.conf.example```
- configure as you like

| option | default | arguments | comment |
|------------------|--------------------------|---------------------|----------------------------------------------------------------------------------------|
| mqtt_host | 'localhost' | -m, --mqtt_host | The hostname of the MQTT server. |
| mqtt_port | 1883 | --mqtt_port | The port of the MQTT server. |
| mqtt_keepalive | 30 | --mqtt_keepalive | The keep alive interval for the MQTT server connection in seconds. |
| mqtt_clientid | 'fronius2mqtt' | --mqtt_clientid | The clientid to send to the MQTT server. |
| mqtt_user | - | -u, --mqtt_user | The username for the MQTT server connection. |
| mqtt_password | - | -p, --mqtt_password | The password for the MQTT server connection. |
| mqtt_topic | 'fronius' | -t, --mqtt_topic | The topic to publish MQTT message. |
| mqtt_tls_version | 'TLSv1.2' | --mqtt_tls_version | The TLS version to use for MQTT. One of TLSv1, TLSv1.1, TLSv1.2. |
| mqtt_verify_mode | 'CERT_REQUIRED' | --mqtt_verify_mode | The SSL certificate verification mode. One of CERT_NONE, CERT_OPTIONAL, CERT_REQUIRED. |
| http_host | 'localhost' | --http_host | The address of the HTTP server. |
| http_port | 8080 | --http_port | The port of the HTTP server. |
| verbose | - | -v, --verbose | Be verbose while running. |
| - | '/etc/fronius2mqtt.conf' | -c, --config | The path to the config file. |
| option | default | arguments | comment |
|--------------------|--------------------------|-------------------------|----------------------------------------------------------------------------------------|
| `mqtt_host` | 'localhost' | `-m`, `--mqtt_host` | The hostname of the MQTT server. |
| `mqtt_port` | 1883 | `--mqtt_port` | The port of the MQTT server. |
| `mqtt_keepalive` | 30 | `--mqtt_keepalive` | The keep alive interval for the MQTT server connection in seconds. |
| `mqtt_clientid` | 'fronius2mqtt' | `--mqtt_clientid` | The clientid to send to the MQTT server. |
| `mqtt_user` | - | `-u`, `--mqtt_user` | The username for the MQTT server connection. |
| `mqtt_password` | - | `-p`, `--mqtt_password` | The password for the MQTT server connection. |
| `mqtt_topic` | 'fronius' | `-t`, `--mqtt_topic` | The topic to publish MQTT message. |
| `mqtt_tls_version` | 'TLSv1.2' | `--mqtt_tls_version` | The TLS version to use for MQTT. One of TLSv1, TLSv1.1, TLSv1.2. |
| `mqtt_verify_mode` | 'CERT_REQUIRED' | `--mqtt_verify_mode` | The SSL certificate verification mode. One of CERT_NONE, CERT_OPTIONAL, CERT_REQUIRED. |
| `http_host` | 'localhost' | `--http_host` | The address of the HTTP server. |
| `http_port` | 8080 | ``--http_port`` | The port of the HTTP server. |
| `timestamp` | - | `-z`, `--timestamp` | Publish timestamps for all topics, e.g. for monitoring purposes. |
| `verbose` | - | `-v`, `--verbose` | Be verbose while running. |
| - | '/etc/fronius2mqtt.conf' | `-c`, `--config` | The path to the config file. |


## Disclaimer

''Attention:'' Please be aware that the data is published over plain HTTP by this solution.
Use with care ond only if you know what you're doing.

## Future plans

- Support for HTTPS
- Authentication support
- Support for new Fronius API

33 changes: 23 additions & 10 deletions fronius2mqtt
Original file line number Diff line number Diff line change
Expand Up @@ -5,6 +5,7 @@ import json
import logging
import os
import ssl
import time
import paho.mqtt.client as mqtt

from bottle import request, route, post, run
Expand Down Expand Up @@ -38,6 +39,12 @@ def extract_request_data():
return data


def publish(topic, payload):
mqtt_client.publish(topic, payload)
if daemon_args.timestamp:
mqtt_client.publish("{}/timestamp".format(topic), time.time(), retain=True)


@route('/')
def index():
return "Hello World!<br/>This is the fronius2mqtt daemon by Gerrit Beine"
Expand All @@ -52,19 +59,19 @@ def current_data_inverter(device):
if 'PAC' in data['Body'] and 'Values' in data['Body']['PAC']:
for k, v in data['Body']['PAC']['Values'].items():
topic = "{}/pac/{}".format(topic_base, k)
mqtt_client.publish(topic, v)
publish(topic, v)
if 'DAY_ENERGY' in data['Body'] and 'Values' in data['Body']['DAY_ENERGY']:
for k, v in data['Body']['DAY_ENERGY']['Values'].items():
topic = "{}/day_energy/{}".format(topic_base, k)
mqtt_client.publish(topic, v)
publish(topic, v)
if 'YEAR_ENERGY' in data['Body'] and 'Values' in data['Body']['YEAR_ENERGY']:
for k, v in data['Body']['YEAR_ENERGY']['Values'].items():
topic = "{}/year_energy/{}".format(topic_base, k)
mqtt_client.publish(topic, v)
publish(topic, v)
if 'TOTAL_ENERGY' in data['Body'] and 'Values' in data['Body']['TOTAL_ENERGY']:
for k, v in data['Body']['TOTAL_ENERGY']['Values'].items():
topic = "{}/total_energy/{}".format(topic_base, k)
mqtt_client.publish(topic, v)
publish(topic, v)
return "OK"


Expand All @@ -78,7 +85,7 @@ def current_data_meter(device):
for k, v in d.items():
if v is not None and type(v) in [int, float, str] :
topic = "{}/{}/{}".format(topic_base, m, k.lower())
mqtt_client.publish(topic, v)
publish(topic, v)
return "OK"


Expand All @@ -92,13 +99,13 @@ def current_data_powerflow(device):
for k, v in data['Body']['Site'].items():
if v is not None:
topic = "{}/site/{}".format(topic_base, k.lower())
mqtt_client.publish(topic, v)
publish(topic, v)
if 'Inverters' in data['Body']:
for i, d in data['Body']['Inverters'].items():
for k, v in d.items():
if v is not None:
topic = "{}/{}/{}".format(topic_base, i, k.lower())
mqtt_client.publish(topic, v)
publish(topic, v)
return "OK"


Expand All @@ -113,14 +120,14 @@ def current_data_storages(device):
for k, v in d['Controller'].items():
if v is not None and type(v) in [int, float, str] :
topic = "{}/{}/{}".format(topic_base, s, k.lower())
mqtt_client.publish(topic, v)
publish(topic, v)
if 'Modules' in d:
for m in d['Modules']:
serial = m['Details']['Serial']
for k, v in m.items():
if v is not None and type(v) in [int, float, str] :
topic = "{}/{}/{}/{}".format(topic_base, s, serial.lower(), k.lower())
mqtt_client.publish(topic, v)
publish(topic, v)
return "OK"


Expand Down Expand Up @@ -152,7 +159,7 @@ def datamanager_io_states(device):
for k, v in d.items():
if v is not None:
topic = "{}/{}/{}".format(topic_base, p.replace(' ', '_'), k.lower())
mqtt_client.publish(topic, v)
publish(topic, v)
return "OK"


Expand Down Expand Up @@ -243,6 +250,10 @@ def parse_args():
parser.add_argument('-c', '--config', type=str,
default='/etc/fronius2mqtt.conf',
help='The path to the config file. Default is /etc/fronius2mqtt.conf')
parser.add_argument('-z', '--timestamp',
default=False,
action='store_true',
help='Publish timestamps for all topics, e.g. for monitoring purposes.')
parser.add_argument('-v', '--verbose',
default=False,
action='store_true',
Expand Down Expand Up @@ -290,6 +301,8 @@ def parse_config():
daemon_args.http_host = data['http_host']
if 'http_port' in data:
daemon_args.http_port = int(data['http_port'])
if 'timestamp' in data:
daemon_args.timestamp = data['timestamp']
if 'verbose' in data:
daemon_args.verbose = data['verbose']

Expand Down

0 comments on commit d150cba

Please sign in to comment.