import os
import os.path
import time
import logging as log
from datetime import datetime
from saleae import automation
# Connect to the running Logic 2 Application on port
manager = automation.Manager(port=10430)
# Configure the capturing device to record on digital channels 0, 1, 2, and 3,
# with a sampling rate of 10 MSa/s, and a logic level of 3.3V.
device_configuration = automation.LogicDeviceConfiguration(
enabled_digital_channels=[0, 1, 2, 3],
digital_sample_rate=10_000_000,
digital_threshold_volts=3.3,
)
# Record 5 seconds of data before stopping the capture
capture_configuration = automation.CaptureConfiguration(
capture_mode=automation.TimedCaptureMode(duration_seconds=5.0)
)
# Start a capture - the capture will be automatically closed when leaving the block
# Note: We are using serial number 'F4241' here, which is the serial number for
# the Logic Pro 16 demo device. You will need to use your device's serial number
# to use a real device. Please see the "Finding the Serial Number of a Device" section.
try:
with manager.start_capture(device_serial_number='F4241',
device_configuration=device_configuration,
capture_configuration=capture_configuration) as capture:
print("Capturing...")
# Wait until the capture has finished
# This will take about 5 seconds because we are using a timed capture mode
capture.wait()
# Add an analyzer to the capture
# Note: The simulator output is not actual SPI data
spi_analyzer = capture.add_analyzer('SPI', label=f'Test Analyzer', settings={
'MISO': 0,
'Clock': 1,
'Enable': 2,
'Bits per Transfer': '8 Bits per Transfer (Standard)'
})
# Store output in a timestamped directory
output_dir = os.path.join(os.getcwd(), f'output-{datetime.now().strftime("%Y-%m-%d_%H-%M-%S")}')
os.makedirs(output_dir)
# Export analyzer data to a CSV file
analyzer_export_filepath = os.path.join(output_dir, 'spi_export.csv')
capture.export_data_table(
filepath=analyzer_export_filepath,
analyzers=[spi_analyzer],
radix=automation.RadixType.ASCII
)
# Export raw digital data to a CSV file
capture.export_raw_data_csv(directory=output_dir, digital_channels=[0, 1, 2, 3])
# Finally, save the capture to a file
capture_filepath = os.path.join(output_dir, 'example_capture.sal')
capture.save_capture(filepath=capture_filepath)
print("Capture exported")
except Exception as e:
print("Got exception %r. Is the Logic GUI running and listening?" % type(e))
manager.close() # We must close the manager thread, or else python will block waiting for it to end
raise e # Be noisy and propagate the exception
manager.close() # No exception occured, but we must still close the manager thread