Skip to content

AIMedLab/stable-prediction

 
 

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

Stable Clinical Risk Prediction against Distribution Shift in Electronic Health Records

Introduction

This repository contains source code for paper "Stable Clinical Risk Prediction against Distribution Shift in Electronic Health Records".

The availability of large-scale electronic health record (EHR) datasets has led to the development of artificial intelligence (AI) methods for clinical risk prediction that help improve patient care. However, existing studies have shown that AI models suffer from severe performance decay after several years of deployment, which might be caused by various temporal dataset shifts (e.g., the distribution of International Classification of Diseases (ICD) code changes when transiting ICD version from ICD-9 to ICD-10). When the dataset shift occurs, we have access to large-scale pre-shift data and small-scale post-shift data that are not enough to train new models in the post-shift environment. In this study, we propose a new method to address the issue for clinical risk prediction. We re-weight patients collected from the pre-shift environment to mitigate the distribution shift between pre- and post-shift environments. Moreover, we adopt a Kullback–Leibler (KL) divergence loss to force the models to learn similar patient representations in pre- and post-shift environments. Our experimental results indicate that our model trained on large-scale pre-shift data outperforms the baselines trained on small-scale post-shift data by about 17% and improves existing models trained with pre-shift data by more than 3.5% with our methods.

Overview

figure1

Figure 1: Illustrations of sample reweighting, clinical risk prediction, and the proposed method. (a) Diagram of clinical risk prediction. (b) Changes in the distribution of medical codes after sample reweighting to mitigate the distribution shift. (c) Architecture of the proposed method for sample reweighting.

Installation

Our model depends on Numpy, scikit-learn, PyTorch (CUDA toolkit if use GPU), and torchmetrics. You must have them installed before using our model.

  • Python 3.9
  • Pytorch 1.10.2
  • torchmetrics 0.7.2
  • Numpy 1.21.2
  • Pandas 1.4.1
  • Scikit-learn 1.0.2

This command will install all the required libraries and their specified versions.

pip install -r requirements.txt

Preprocessing data

Dataset

Please be informed that the dataset utilized in this study is derived from MarketScan claims data. To obtain access to the data, interested parties are advised to contact IBM through the following link.

Input data demo

For your convenience, a demo version of the input data can be found in the data folder. It includes the data structures and a synthetic demonstration of the inputs. Prior to executing the preprocessing codes, please ensure that the format of your input data matches the format provided in the input demo.

The detailed descriptions of each variable in the dataset can be found in the README.md in the data folder. Please refer to the README.md for comprehensive explanations of the dataset variables.

Preprocess

The demo dataset serves solely as a reference for the input data format. It is not possible to run the training code using preprocessed data from the demo dataset. Please utilize the preprocessed data provided in the "pickles" folder to run the training code.

python preprocess/run_preprocessing.py --input_dir 'data' --pred_windows 90 180 --min_visits 10

Parameters

  • input_dir: path to datset.
  • pred_windows: prediction windows.
  • min_visits: minimum number of visits for each patient.

Training and test

Python command

To run the training code using the provided data, please use the parameters --time 90 and --target 'HF'

# Note: Here's just a demo case for parameter selection. They can be easily adjusted for different application scenario. 
python train.py --config 'json/Dipole.json' --model 'Dipole' --target 'HF' --version 'weight' --time 90 --day_dim 100 --rnn_hidden 100 --steps 500 --weight_decay 0.001 --step_lr 0.001 --dist_weight 1e+7 --kl_weight 1e+4 --kl_dim 64

Parameters

Hyper-parameters are set in config/*.json

  • early_stop: the number of epochs for early stopping
  • monitor: the criterian for early stopping. The first word is 'min' or 'max', the second one is metric
  • metrics: metrics to print out. It is a list format.
  • valid_ratio: the ratio of validation set

Hyper-parameters are set in train.py

  • version: from {'basic', 'weight'}. 'basic' and 'weight' are to run the baseline and our model, respectively.
  • model: baseline model from {'GRU', 'LSTM', 'Dipole', 'Retain', 'Stagenet', 'Concare', 'DG', 'AdaDiag'}
  • config: json file to use
  • target: target disease related to the input data
  • time: prediction window related to the input data
  • day_dim: the dimension of the embedding layer. It works for {'Dipole', 'GRU', 'LSTM'}
  • rnn_hidden: the number of hidden features in recurrent layers. It works for {'Dipole', 'GRU', 'LSTM', 'Retain'}
  • weight_decay: weight decay when training the predictive model (baseline)
  • steps: the number of epochs to learn sample weights
  • step_lr: learning rate to learn sample weights
  • kl_dim: the number of hidden features in Autoencoder of the proposed method
  • kl_weight and dist_weight: weights to control KL and MSE losses, respectively

About

No description, website, or topics provided.

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

 
 
 

Languages

  • Python 100.0%