Implement the total field anomaly function. Add to the api index.
harmonica/_utils.py
Outdated
>>> print(tfa) | ||
50000.0 | ||
""" | ||
b_e, b_n, b_u = magnetic_field |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
You could add a small check to control that the parameter declination
is indeed in degree.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Thanks for the suggestion @VascoSch92. It's hard to implement such checks. There's no way we can identify if the user passed an angle in radians or in degrees, besides making assumptions upon its value. I think documenting the argument properly, and keeping the consistency among the package (all inclination and declination angles, along with all longitude and latitude angles in Harmonica as expected in degrees) is enough to make users aware what is expected for these arguments.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
you are right :-)
Implement the total field anomaly function. Add to the api index.
Relevant issues/PRs:
Fixes #506